Drop Vertical Jump
Landing mechanics from a controlled drop, followed by an immediate jump.
- 16
- metrics
- 0
- gradable today
- 9
- events detected
What it tests, what QOOM measures, what you get
- What it tests
- Landing mechanics from a controlled drop, followed by an immediate jump.
- What QOOM measures
- Drop-to-contact and contact time, jump height, RSI, knee flexion at contact, peak knee flexion, peak dynamic knee valgus, trunk lean and flexion at landing, landing asymmetry.
- What you get
- Landing-focused report with left/right comparison and metric zones.
The protocol
Two phones on tripods, stereo-calibrated once. The protocol below is the one the analysis pipeline is written against.
Subject stands on a box (30-40 cm), drops off, lands on both feet, immediately performs a maximal vertical jump, and lands again. Arms overhead or hands on hips per protocol. One trial per attempt.
- Category
- Jump
- Environment
- Any space
- Trial structure
- Single repetition, repeated as needed
- Minimum capture
- 2 s
The moments the analysis finds first
Every metric is measured between events. These are detected from the reconstructed skeleton before any metric is computed.
- 1
Trial Start
trial_startFirst frame of the captured trial.
- 2
Drop Initiation
drop_initiationFrame where the subject begins to step/fall off the box.
- 3
First Landing
first_landingFrame of first ground contact after the drop.
- 4
Amortization End
amortization_endFrame where downward COM velocity reaches zero after first landing (deepest point of the loading phase).
- 5
Jump Take-Off
jump_takeoffFrame where feet leave the ground for the reactive vertical jump.
- 6
Flight Peak
flight_peakFrame of maximum COM height during the reactive jump flight phase.
- 7
Second Landing
second_landingFrame of ground contact after the reactive jump.
- 8
Stabilization Start
stabilization_startFrame where COM velocity settles below threshold after second landing.
- 9
Trial End
trial_endLast frame of the captured trial.
The full metric list
This is the complete list the analysis produces for this assessment — the same list the metric reference documents. A metric with a reference distribution shows the direction that reads as better and the evidence level behind it; where the evidence gate withholds the zone, the reason is shown instead of a grade.
- Drop-to-Contact Timems
drop_to_contact_msNo reference distributionTime from drop initiation to first landing.
- Contact Timems
contact_time_msZone withheld — no recorded sourceevidence:approximateGround contact time from first landing to jump takeoff (amortization + propulsion).
- Jump Heightcm
jump_height_cmZone withheld — source not resolved to a specific paperevidence:approximateMaximum COM height during the reactive jump flight phase relative to standing.
- Reactive Strength Index—
rsiZone withheld — no recorded sourceevidence:approximateJump height divided by contact time. Measures reactive ability.
- Knee Flexion at Contact°
knee_flexion_at_contact_degPer sideNo reference distributionKnee flexion at first landing. Soft-landing indicator.
- Peak Knee Flexion°
peak_knee_flexion_degPer sideZone withheld — no recorded sourceevidence:approximateMaximum knee flexion during the amortization phase.
- Peak Dynamic Knee Valgus°
peak_dynamic_knee_valgus_degZone withheld — metric does not measure the reference quantityevidence:consensusMaximum medial knee collapse at first landing. The primary landing-alignment marker of the drop vertical jump.
- Trunk Lean at Landing°
trunk_lean_at_landing_degZone withheld — no recorded sourceevidence:approximateLateral trunk lean at first landing.
- Trunk Flexion at Landing°
trunk_flexion_at_landing_degZone withheld — no recorded sourceevidence:approximateForward trunk flexion at first landing.
- Landing Asymmetry%
landing_asymmetry_pctNo reference distributionPercentage difference in left vs right knee flexion at first landing. Left/right landing asymmetry marker.
- Pelvis Vertical Excursionm
pelvis_vert_excursion_mNo reference distributionTrial-aggregate range of vertical pelvis-COM motion. Indexes how much the centre of mass rises and falls relative to the support base.
- Pelvis Lateral Excursionm
pelvis_lateral_excursion_mNo reference distributionTrial-aggregate range of medio-lateral pelvis-COM motion. Quantifies side-to-side sway, including during single-leg stance.
- Pelvis Forward Excursionm
pelvis_forward_excursion_mNo reference distributionTrial-aggregate range of anterior-posterior pelvis-COM motion. Forward progression in gait; forward travel and braking depth in jumps.
- Pelvis Vertical Excursion (SD)m
pelvis_vert_excursion_sd_mNo reference distributionCross-cycle (or cross-rep) standard deviation of vertical pelvis-COM excursion. Higher SD signals movement variability.
- Pelvis Lateral Excursion (SD)m
pelvis_lateral_excursion_sd_mNo reference distributionCross-cycle standard deviation of lateral pelvis-COM excursion. Used as a stability marker for repeated gait/jump tasks.
- Pelvis Forward Excursion (SD)m
pelvis_forward_excursion_sd_mNo reference distributionCross-cycle standard deviation of forward pelvis-COM excursion. Used as a stability marker for repeated gait/jump tasks.
Sections of the report
The per-trial report is assembled from these sections, in this order.
- 1
Key Metrics
Headline DVJ metrics.
- 2
Metric Zone Overview
All metrics as gradient zone bars.
- 3
Phases & Events
COM vertical position with all DVJ phase markers.
- 4
Joint Kinematics
Knee, hip, trunk kinematics through the drop-land-jump sequence.
- 5
Description of Metrics
Full-text description of every metric in the report and what each one measures.
- 6
Quality Assurance
QA verdict, reasons, warnings, schema version, report hash.
What can stop a result
Each trial is checked before metrics are reported. A failed check either blocks the result or marks it partial — it is never silently graded.
- Blocked
Mean pose-estimation confidence across trial must be >= 0.60
min_pose_confidence - Partial
No contiguous occlusion > 0.5 s on key landmarks (hip, knee, ankle)
no_major_occlusion - Partial
All 9 events must be detected with confidence >= 0.5
dvj_all_events - Blocked
Both first and second landing must be detected
dvj_two_landings - Blocked
A reactive jump (takeoff after first landing) must occur
dvj_reactive_jump - Blocked
Drop phase must show >= 0.15 m vertical COM descent
dvj_drop_height
- Blocked —
- No metrics are reported for the trial.
- Partial —
- Metrics are reported with a warning; the affected values are flagged.
When a metric gets a zone
A metric can be graded only when the norms registry holds a reference distribution for it, and a zone is shown only when the evidence gate admits that distribution’s provenance and evidence level. A distribution the gate refuses stays in the registry, auditable, with no zone.
0 of 16 metrics can be graded today
7 carry a reference distribution · 7 zones withheld by the evidence gate: 5 × no recorded source, 1 × source not resolved to a specific paper, 1 × metric does not measure the reference quantity
Evidence levels behind this assessment’s reference distributions
published0Values traceable to a peer-reviewed population study. Reserved; nothing in the registry currently qualifies.
consensus1Anchored to a recognised clinical guideline or expert-consensus cutoff. Values are approximate, but the cutoff is citable.
approximate6Informal literature ranges or general-adult estimates, not validated against a specific cohort. The honest default.
unvalidated0A two-point estimate or an inferred value. A distribution is declared, but the evidence gate withholds the zone.
Run this assessment.
Two phones, one guided protocol, and a report at the end.